Volkswagen Golf Service & Repair Manual: Supplementary heating mode

Once the coolant temperature has reached approx. 84 °C, the control unit switches to energy-saving control mode. If the coolant temperature continues to rise above approx. 88 °C, the control unit switches to the controlled waiting period. If the coolant temperature does not drop below approx. 76 °C within 15 minutes during the controlled waiting period, the heater unit will initiate the start procedure into the standard control mode when the coolant temperature does drop below approx. 76 °C.
   
Functional description
The auxiliary and supplementary heater can be started by means of the remote control, the instant heating button or appropriate programming in the central monitor. Th ...

Auxiliary heater mode
Switching on auxiliary heater mode in vehicles with manual air conditioning: –  Press instant heating button-1-.   ...

Other materials:

Checking holding pressure
Special tools and workshop equipment required Removal wedge -3409- Pressure tester -VAS 6550- Connector cable -VAS 6550/3-3- Connector cable -VAS 6550/3-4- Vehicle diagnostic tester   ...

Removing and installing fuse holder, battery
Removing –  With ignition switched off, disconnect earth cable from battery → Chapter.     –  Open cover -1-. –  ...

Assembly overview - control unit and hydraulic unit, RHD vehicles
1 -  Brake servo and brake master cylinder Assembly overview → Chapter. Checking brake servo → Vehicle diagnostic tester Removing and installing → Chapter Removi ...