1 -  Exhaust ventilation for passenger compartment
Checking → Chapter
Removing and installing → Chapter
2 -  Humidity sender for air conditioning system -G260-
Check via onboard supply control unit -J519-vehicle diagnostic tester in “Guided fault finding” mode and → Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter
3 -  Fresh air intake
Removing and installing → Chapter
4 -  Air quality sensor -G238-
Check using vehicle diagnostic tester in “Guided fault finding” mode and → Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter
Principles of operation → Chapter
Only on vehicles with Climatronic.
5 -  Cover for fresh air intake duct
Removing and installing → Chapter
6 -  Expansion valve
Removing and installing → Chapter
Specified torques → Chapter
7 -  Desiccant bag
Removing and installing → Chapter
Assembly overview → Chapter
8 -  Ambient temperature sensor -G17-
Check via onboard supply control unit -J519-vehicle diagnostic tester in “Guided fault finding” mode and → Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter
9 -  Condenser
With integrated receiver
Assembly overview → Chapter
Removing and installing → Chapter
  Note
Under certain conditions, it is not necessary to renew the receiver with desiccant bag every time that the refrigerant circuit is opened. Refer to ELSA under Heating, ventilation, air conditioning system; Air conditioning system with refrigerant R134a → Air conditioning system with refrigerant R134a; Rep. gr.00.
10 -  Air conditioner compressor
Assembly overview → Chapter
Removing and installing → Chapter
Removing from and installing on bracket → Chapter
11 -  Evacuating and charging valve, high-pressure side
Removing and installing → Chapter
12 -  Pressure sender for refrigerant circuit -G805-
8 Nm
Checking: Use vehicle diagnostic tester in “Guided fault finding” mode and → Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter
13 -  Evacuating and charging valve, low-pressure side
Removing and installing → Chapter
14 -  Refrigerant line with internal heat exchanger
From condenser and air conditioner compressor
Removing and installing → Chapter
Overview of fitting locations - components not located in passenger compartment, Golf Variant LHD
1 -  Exhaust ventilation for passenger compartment Checking → Chapter Removing and installing → Chapter ...

Overview of fitting locations - components located in front section of passenger compartment
...

Other materials:

Assembly overview - dash panel insert
1 -  Electrical connector For dash panel insert 2 -  Dash panel insert -KX2- With control unit in dash panel insert -J285-. Dash panel insert must be renewed if warning lamp LED or illumination ...

Overview of fitting locations - injection system
Overview of fitting locations - engine compartment 1 -  Inlet camshaft control valve 1 -N205- Removing and installing → Chapter 2 -  Exhaust camshaft control valve 1 -N318- Only installe ...

Assembly overview - cover and padding for backrest
1 -  Upholstery clip For attaching backrest cover to backrest padding Renew after removal When installing, fit in same location using upholstery clip pliers -V.A.G 1634 2 -  Beading strip Sewn to backrest cover Seats with th ...