VW Golf manuals

Volkswagen Golf Service & Repair Manual: Connecting air conditioner service station

For vehicles that have connections on both low-pressure and high-pressure sides of refrigerant circuit
Connecting air conditioner service station for measuring and checking
–  Switch off ignition.
–  Connect air conditioner service station to power supply.
–  Connect quick-release coupling adapters to charging hoses for air conditioner service station (handwheels not turned inwards, i.e. hand shut-off valves not open).
–  Switch on air conditioner service station and evacuate charging hoses (necessary only if there is air in the charging hoses).
–  Switch off air conditioner service station.
–  Unscrew sealing caps from service connections (with valve).
–  Connect air conditioner service station via service connections to the vehicle refrigerant circuit using quick-release coupling adapter.
–  Turn handwheel of quick-release coupling adapter inwards only far enough to ensure that valves on service connections are open (check using a pressure gauge; do not overstress valves).
–  Perform the intended measuring and checking work.
Spraying the evaporator with the suction feed spray-gun -V.A.G 1538- and spray lance
Spray the evaporator with Contra Sept directly using a spray lance (approx. 10 bar). Contra Sept neutralises microbes and bacteria directly at the evaporator. ...

Checking pressures on vehicles
...

Other materials:

Removing and installing charge air cooler
Special tools and workshop equipment required     Hose clamps up to 25 mm -3094-   Drip tray for workshop hoist -VAS 6208- ...

Renewing needle bearing in crankshaft
Only vehicles with a dual clutch gearbox Special tools and workshop equipment required     Adapter Kukko -22/1-   ...

Charging battery
  WARNING Danger of injury! Observe warning notices and safety regulations → Chapter!   Caution To prevent damage to ...

© 2016-2024 Copyright www.vwgolf.org