Volkswagen Golf Service & Repair Manual: Checking auxiliary air heater element -Z35- with auxiliary air heater
control unit -J604-, LHD vehicles
Special tools and workshop equipment
required |
Vehicle diagnostic tester with current probe 100 A -VAS
5051B/7- |
Intake temperature less than 19° C |
Coolant temperature less than 80° C |
Passenger compartment temperature about 20° C |
Battery voltage greater than 11 V |
Alternator load not greater than 50 % (terminal DF) |
Engine speed greater than 450 rpm |
Turn rotary knob for interior temperature to highest
temperature (on vehicles with Climatronic select highest level). |
– |
Remove left centre console trim in footwell
→ General body repairs, interior; Rep. gr.68. |
|
|
|
– |
Using vehicle diagnostic tester and current probe 100 A -VAS
5051B/7-, measure current draw -arrow-
on earth wire -1- of auxiliary air
heater element -Z35--2-. |
Low heat output ≈ 30 amps |
Medium heat output ≈ 60 amps |
High heat output ≈ 80 amps |
|
|
|
Note
If only the fresh air blower -V2- is defective, remove and
install fresh air blower control unit -J126-
→ Chapter.
...
Checking
Special tools and workshop equipment
required
Vehicle diagnostic tester with current probe 100 A -VAS
505 ...
Other materials:
Introduction
This chapter contains information on the following subjects:
→ Displays
→ Description
ProActive occupant protection is an assistance system that initiates action to
protect vehicle occupants in dangerous situations. However, the system cannot prevent
a collision.
Add ...
Checking pistons and cylinder bores
Checking piston
–
Using a micrometre, measure approx. 10 mm from the lower
edge, perpendicular to the piston pin axis.
Maximum deviation from nominal dimension: 0.04 mm
...
Removing and installing anti-theft alarm sensor -G578-, version with 2 bolts
Removing
–
Remove front interior light -WX1-
→ Chapter.
–
Remove bolts -2-.
–
Remove roof module -1- in
...